West-control-solutions CI 45 User Manual

Browse online or download User Manual for Equipment West-control-solutions CI 45. West Control Solutions CI 45 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PMA Prozeß- und Maschinen-Automation GmbH
UNIFLEX CI 45
universal transmitter
UNIFLEX
UNIFLEX
CI 45
CI 45
Operating manual
English
9499-040-71711
Valid from: 06/2009
rail
line
Page view 0
1 2 3 4 5 6 ... 59 60

Summary of Contents

Page 1 - UNIFLEX CI 45

PMA Prozeß- und Maschinen-Automation GmbHUNIFLEX CI 45universal transmitterUNIFLEXUNIFLEXCI 45CI 45Operating manualEnglish9499-040-71711Valid from: 06

Page 2 - ATTENTION!

.4Electrical connections4.1 Connecting diagram4.2 Terminal connectionsaFaulty connection might cause destruction of the instrument !1 Connecting the s

Page 3 - Table of content

2 Connecting input INP1Input for the measurement valuea resistance thermometer (Pt100/ Pt1000/ KTY/ ...), 3-wire connection terminal: 1, 2, 3b resista

Page 4 - 4 UNIFLEX CI 45

4.3 Connecting diagramThe instrument terminals used for the engineering can be displayed and printed out via BlueControlÒ( menu File \ Printpreview -

Page 5 - Applications

4.5Hints for installationwMeasurement and data lines should be kept separate from control and power supply cables.wSensor measuring cables should be t

Page 6 - Safety hints

.5Operation5.1 Front view1 Line 1: process value display2 Line 2: display of unit / extended operating level / error list /Conf and PArA level values3

Page 7 - 2.3 Spare parts

5.2 Operating structureThe instrument operation is divided into four levels:The access to the parameter, configuration and calibrating level can be di

Page 8 - Mounting

5.4.2 Display line 2The value to be displayed continuously in the second LCD line can be selected via the BlueControlÒengineeringtool.As default, the

Page 9 - Connectors

5.4.4 Slave pointer functionThe minimum and maximum input values are stored in the unit.The minimum input value is displayed as long as key Ì ispresse

Page 10 - 4.2 Terminal connections

5.4.6 Extended operating levelThe operation of important or frequently used parameters and signals can be allocated to the extended operating level.Th

Page 11

.6FunctionsThe signal data flow of transmitter CI 45 is shown in the following diagram:6.1 LinearizationThe input values of input INP1 or INP2 can be

Page 12 - Connection examples

© 2004 PMA Prozeß- und Maschinen-Automation GmbH · Printed in GermanyAll rights reserved. No part of this document may be reproduced or published in a

Page 13

gThe same linearization table is used for input 1 and input 2.6.2 Input scalingScaling of input values is possible. After any linearization, measureme

Page 14 - Front view

aFor using the pre-defined scaling with thermocouples and resistance thermometers (Pt100), the settingsfor InL and OuL as well as for InH and OuH must

Page 15 - Operating level

6.3 Temperature compensation, measured via INP2 (optional)With thermocouple measurement via INP1, the required temperature compensation is possible by

Page 16 - 5.4.2 Display line 2

6.4 FilterA 1st order mathematical filter with adjustable time constant and bandwidth is built in.The filter bandwidth b.Fx is the adjustable toleranc

Page 17 - 5.4.5 Selecting the units

A non-heated l probe is used, if the temperature is not constant. In this case, the temperature in addition to theprobe mV value must be measured. For

Page 18 - Extended operating level

DisplaysWith configuration for O2 measurement (see above), the oxygen content is displayed as process value with the selectedunit (see above) on line

Page 19 - Linearization

gNote that the counter end must be set to a lower value than the counter start (Cnt.S > Cnt.E)Resetting the counterThe counter can be reset to the

Page 20 - Input scaling

ScalingThe frequency input value can be scaled to a physical value in two points.1st value:–input Frq.L (value specified in kHz)–physical value Ou.L2n

Page 21 - 6.2.2 Two-wire measurement

6.11 Tare function (optional)Switching on the tare function sets the instantaneous input value to zero and measurement is continued with thisoffset. B

Page 22 - Functions - preliminary

6.13 Integrator functionThe input signal can be totalized by means of a selectable integrator (ConF \ Func \ Fnc.3 = 3).Function:Integrator with adjus

Page 23 - 6.7 O2 measurement (optional)

UNIFLEX CI 45 3Table of content1. General ...52. Safety hints ...62.1

Page 24 - Connection

6.14.1 Measured value monitoringgThe signal to be monitored can be selected separately for each alarm in the configuration. The followingsignals are a

Page 25 - Cnt.E = off

Alarm delayAn alarm can become effective with a delay: the alarm output is set only after elapse of the adjusted delay time,provided that the limit va

Page 26 - Frequency input (optional)

gWith measurement value or signal change with latch selected ( ConF / Lim / Fnc.x=2, 4),the alarm relay remains set, until the alarm was reset in the

Page 27 - 6.10 Arithmetic functions

6.15 Analog output configuration6.15.1 Analog outputThe two output signals (current and voltage) are available simultaneously. Adjust ConF / Out.3 / O

Page 28 - Tare function (optional)

6.15.2 Logic outputThe output can be used also as a logic output (O.typ = 0). In this case, e.g. alarms or limit values can be output.6.15.3 Transmitt

Page 29 - Limit value processing

6.15.4 Frequency output (optional)The analog output signal for voltage can be selected also as a frequency output with setting:ConF / Out.3: O.tYP = 6

Page 30 - Input value monitoring

6.16 Maintenance manager / error listIn case of one or several errors, the error list is always displayed at thebeginning of the extended operating le

Page 31 - Signal change monitoring

gLatched alarms Lim1/2/3 (E element displayed) can be acknowledged, i.e. reset via digital alarm di1.For Configuration, see page 46: ConF / LOGI / Err

Page 32 - Number of switching cycles

.7Configuration level7.1 Configuration surveyDependent on the device version and further adjusted configurations, configurationdata can be hidden.Data

Page 33 - 6.15.1 Analog output

7.2 ConfigurationsDependent on instrument version and configuration settings, display of values which are not required is suppressed.µ The entries mar

Page 34 - 6.15.2 Logic output

4 UNIFLEX CI 456.15 Analog output configuration ...336.15.1 Analog output ...336.15.2 Logic out

Page 35 - 6.15.5 Analog output forcing

Name Value range Description24 Special 0...450 Ohm25 Special 0...1600 Ohm26 Special 0...160 Ohm30 0...20mA / 4...20 mA40 0...10V / 2...10 V (Inp.1 onl

Page 36

Limit values Lim1 … Lim3Name Value range DescriptionFnc.1(Fnc.2)(Fnc.3)Function of limit 1 (2, 3)0 Switched off1 Measured value monitoring2 Measured v

Page 37 - + Power on

Name Value range DescriptionInf.2 Status message Inf.2 (number of switching cycles) (visible only with BlueControl!)0 Not active1 ActiveOutput Out.3 (

Page 38 - Configuration survey

Name Value range DescriptionO.SrcSignal source for analog output OUT3 (only visible with O.TYP=1..4 )0 Not active3 Process value7 Measured value INP18

Page 39 - Configurations

Name Value range DescriptiontArATare-function µ (function must be activated (CONF /FUNC / Fnc.3 = 1))0 No function (switch-over via interface is possi

Page 40 - Counter / frequency input µ

Name Value range DescriptionPrtYData parity on the interface µ0 no parity (2 stop bits)1 Even parity2 odd parity3 no parity (1 stop bit)dELY0...200 De

Page 41 - Limit values Lim1 … Lim3

Name Value range DescriptionFrEq Switching 50/60 Hz (only visible with BlueControl!)0 Mains frequency 50 Hz1 Mains frequency 60 HzILat suppress error

Page 42 - Output Out.3 (analog)

.8Parameter setting level8.1 Parameter surveyDependent on instrument version, display of parameters which are not required is suppressed.8.2 Adjustmen

Page 43 - Logic LOGI

8.3 Parametersµ The entries marked with this symbol are selectable only with the instrument option fitted.Function selection FuncName Value range Desc

Page 44 - Other othr

.9Calibrating levelAdaptation of the measurement value is possible in the calibrating menu ( CAL).gMeasured value correction ( CAL) is accessible only

Page 45 - Configuration level

.1GeneralThank you very much for buying a Universal Transmitter UNIFLEX CI 45.UNIFLEX CI 45 transmitters are suitable for precise, cost-efficient sign

Page 46 - Linearization Lin

9.1 Offset correctionOffset correction shifts the input value by a pre-defined value.Parameter setting:( ConF/ InP/ Corr =1 ):wOn-line offset correcti

Page 47 - Adjustment

9.2 2-point correction2-point correction can change the offset and gradientofthe input curve.Parameter setting:( ConF/ InP/ Corr = 2 ):w2-point correc

Page 48 - Parameters

.10BlueControlÒengineering toolThe BlueControlÒengineering tool is the projecting environment for the PMA BluePortâinstrument series and for therail l

Page 49 - Calibrating level

.11VersionsAccessories delivered with the transmitter:•Operating note•Rail-to-bus connector for the interface optionAdditional equipment with ordering

Page 50 - Offset correction

.12Technical DataINPUTSUNIVERSAL INPUT INP1Resolution: >15 bitsDecimal point: 0 to 3 decimalsDigital input filter: adjustable 0.0...999.9 sScanning

Page 51 - ( ConF/ InP/ Corr = 2 ):

Thermocouples (Table 1)Cold-junction compensation-Internal,Additional error:typ.:max.:ß_ 0,5 Kß -2,5 K-external,- constant value 0...100 °CFurther tec

Page 52 - BlueControl

Control inputConfigurable as a direct or inverse switch or key!Functions: Locking front operating,resetting of latched alarms, slave pointers,integrat

Page 53 - Versions

Frequency outputOutput by means of voltage outputFrequency range: 0, 0.25 ...1000 Hz (square-wave signal)Output value: scalableLevel: 0 / 11,5VPulse o

Page 54 - (UNIVERSAL, OPTION)

Permissible temperaturesFor specified accuracy: -10...55°CWarm-up time: < 20 minutesTemperature effect: ß 0.05% / 10 Kadd. influence to coldjunctio

Page 55 - Designed as:

.13Index59 UNIFLEX CI 450-9-2-point-correction 51A-accessories 53-additional equipment 53-alarm delay 30-analog output 33-applications 5-arithmetic fu

Page 56 - Counter input (optional)

.2Safety hintsThis instrument was built and tested in accordance with VDE 0411-1 / EN 61010-1 and was shipped in safe condition.The unit complies with

Page 57 - Max. permissible voltages:

A4, geheftet, SW-Druck, Normalpapier 80g weiß9499- 040- 71711Subject to alterations without notice © PMA Prozeß- und Maschinen-Automation GmbHÄnderung

Page 58 - CE certified

aWarningWhen opening the instruments, or when removing covers and components, live parts or terminals can be exposed.lCautionWhen opening the instrume

Page 59 - 59 UNIFLEX CI 45

.3MountingThe unit is provided for vertical mounting on 35 mm top-hat rails to EN 50022.If possible, the place of installation should be exempt of vib

Page 60 - 9499- 040- 71711

3.1 ConnectorsThe four instrument connectors are of the plug-in type. They plug into the housing from top or bottom and click inposition. Releasing th